In stock
SKU
TYCORFII

Tyco RFII White Fire Sprinkler Cover Plate 139F

Tyco Cover Plate Assembly For RFII 139 Degree
$10.00
  • Buy 10 for $9.00 each and save 10%
Part NumberTemperaturesApprovals / Listings
TYCORFII139° F (59° C)UL, ULc, FM
Cover Plate FinishFire SprinklerStock Status
Bright White

RFIIIn Stock

Product Details

Tyco ROYAL FLUSH II flat cover plate for quick and standard response fire sprinkler model RFII concealed. When a cover plate reaches a specified temperature the solder holding the decorative exterior of the cover plate to its frame melts and the two separate. The temperature of the cover plate should be at a minimum 20°F cooler than the sprinkler head itself ensuring adequate separation time prior to sprinkler activation.

Fits Tyco Models: TY3551, TY3531, TY3532*, C2596*, TY3555*, TY3535*, TY3539*

*UL, cUL Listings Only

Not the fire sprinkler cover plate you're looking for? See all sprinkler covers.

Tyco RFII fire sprinkler cover plate is available online in one temperature:

139° F, 59° C

Tyco RFII fire sprinkler concealer plate available online in three finishes:

White Painted, Chrome Plated, Black Painted

*Black and other colors available by special request. All special request cover plates are special order and are non-refundable, non-returnable.

Fire sprinkler cover plate listings:

UL Listed, ULc Listed, FM Approved

Can I paint my fire sprinkler cover plate?

Fire Sprinkler Helpful Tips:

Tip 1: When replacing cover plates it is important to purchase replacements from the same manufacturer as the fire sprinkler. Each manufacturer's plate is a little different in size, color, etc. Manufacturer and temperature of a cover plate is printed on the base of the plate requiring removal to inspect. Most cover plates are either twist off or pull off.

Tip 2: It is recommended that a qualified professional replace fire sprinklers or in any other way modify a fire sprinkler system.

Tip 3: Spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often state regulations apply, too. Check with your local fire department.

Tip 4: Fire sprinkler systems should be visually inspected often and professionally inspected annually.

Tyco Rapid Response Fire Sprinkler Data Sheet

More Information
Extra Field 8
N/A
Extra Field 9
N/A
Extra Field 10
N/A
Extra Field 11
N/A
Extra Field 12
N/A
Extra Field 7
N/A
Extra Field 6
N/A
Extra Field 5
N/A
Extra Field 4
N/A
Extra Field 3
N/A
Extra Field 2
N/A
Extra Field 1
N/A
Extra Field 13
N/A
Write Your Own Review
You're reviewing: Tyco RFII White Fire Sprinkler Cover Plate 139F
Your Rating
Copyright © 2017 QRFS, LLC. All rights reserved
To Top